Learn guide · Adams Heating & Cooling Team · Updated November 19, 2026

By Adams Heating & Cooling Team Published

Quick answer

R-454B and R-32 are A2L refrigerants, meaning lower toxicity and lower flammability under ASHRAE Standard 34, that replace R-410A in new home air conditioners and heat pumps. Since January 1, 2025, EPA has limited new residential AC and heat pump equipment to refrigerants with a global warming potential below 700. A 2026 rule removed the installation deadline for systems built from pre-2025 components, and working R-410A systems need not be replaced.

Published · Reviewed

Part of our AC Installation & Replacement guides.

This guide is general information, not legal advice. Permit rules change — confirm current requirements with your local building department before work begins.

What are A2L refrigerants like R-454B and R-32?

R-454B and R-32 are the refrigerants replacing R-410A in new home air conditioners and heat pumps, and both carry the A2L safety class. That class comes from ASHRAE Standard 34, which sorts refrigerants by toxicity (A is the lower-toxicity group) and by flammability (classes 1, 2L, 2 and 3). "2L" is the lower-flammability class just above non-flammable class 1.

The change is driven by global warming potential (GWP), a measure of how much heat a gas traps compared with carbon dioxide. Under the U.S. EPA's Technology Transitions rule, new residential and light commercial air conditioning and heat pump equipment must use a refrigerant with a GWP below 700. R-454B and R-32 both fall under that limit; R-410A does not.

R-454B and R-32 are A2L refrigerants: lower toxicity and lower flammability under ASHRAE Standard 34, with a global warming potential below EPA's 700 limit for new home AC and heat pump equipment.

When did the switch from R-410A happen, and does it affect your next system?

The switch applies to new equipment: EPA's 700 GWP limit took effect for the manufacture and import of residential and light commercial AC and heat pump equipment on January 1, 2025. If you replace a central air conditioner or heat pump now, the new system will most likely use R-454B or R-32.

The installation side changed in 2026. EPA had set an installation deadline for systems built from components made before 2025, which a 2023 rule pushed from January 1, 2025 to January 1, 2026. A final rule published in the Federal Register in May 2026 (91 FR 31284), effective July 27, 2026, removed that deadline. Equipment that was manufactured in or imported into the United States before January 1, 2025 can continue to be installed.

So you may still be offered an R-410A system built from that earlier inventory, and that is allowed. What you will not see is newly manufactured R-410A home AC or heat pump equipment.

As of July 27, 2026, residential AC and heat pump systems built entirely from components made or imported before January 1, 2025 have no installation deadline under EPA's Technology Transitions rule.

Do you have to replace your working R-410A air conditioner?

No — EPA's Technology Transitions limits apply to new equipment being manufactured, imported and installed, not to the R-410A system already running in your home. A working R-410A air conditioner or heat pump can keep being repaired and maintained.

The question comes up when a major part fails on an older system. That is a repair-or-replace decision about age, condition and cost, not a legal requirement to switch refrigerants. If a slow leak is part of the picture, our blog post on how refrigerant leaks show up on late-summer energy bills covers the warning signs.

The refrigerant transition restricts new equipment; it does not require homeowners to replace a working R-410A system.

What can go wrong when mixing old and new refrigerant equipment?

The main risk is a mismatched system. Split air conditioners and heat pumps are designed and rated as matched indoor and outdoor components for one refrigerant, so a new R-454B or R-32 outdoor unit generally needs indoor equipment designed for that same refrigerant. Expect a refrigerant change to mean replacing both halves of the system, not just the outdoor unit.

Other points to watch:

  • Charging with the wrong refrigerant. A system is charged with the refrigerant on its nameplate. Refrigerants are not interchangeable between systems.
  • Skipping the permit. Replacing HVAC equipment typically needs a mechanical permit from your local building department (the City of Portage, for example, requires one to replace a mechanical system), and the 2021 Michigan Mechanical Code has governed that work since March 12, 2024. A2L equipment is installed under the same permit process; see HVAC and Water Heater Permits in Kalamazoo County: Who Issues Them and When You Need One.
  • Reading old claims. Articles written before July 2026 may say R-410A systems cannot be installed after 2026. That deadline was removed for systems built from pre-2025 components.

Split AC and heat pump systems are rated as matched indoor and outdoor components for a single refrigerant.

What efficiency minimums apply to a new AC or heat pump in Michigan?

Separate from refrigerant rules, U.S. Department of Energy efficiency standards set minimums by region, and Michigan is in the North region. There, a new split-system central air conditioner must be at least 13.4 SEER2, and a new split-system heat pump must be at least 14.3 SEER2 and 7.5 HSPF2.

Heating matters more than cooling here. Kalamazoo sits in IECC climate zone 5A, and its 1991–2020 normals show 6,326 heating degree days against 710 cooling degree days, according to the National Weather Service. That balance is why heat pump heating performance (HSPF2) deserves as much attention as cooling efficiency when you compare systems.

In the DOE North region, which includes Michigan, new split-system heat pumps must meet at least 14.3 SEER2 and 7.5 HSPF2.

How should you plan your next AC or heat pump around the new refrigerants?

Ask direct questions when you compare quotes, and write the answers down. A short checklist:

  1. Which refrigerant does each quoted system use: R-454B, R-32 or R-410A?
  2. If R-410A, was the equipment manufactured or imported before January 1, 2025?
  3. Are the indoor and outdoor components a matched system for that refrigerant?
  4. Does each system meet or exceed the North-region minimums (13.4 SEER2 for AC; 14.3 SEER2 and 7.5 HSPF2 for heat pumps)?
  5. Which local office issues the mechanical permit, and who will apply for it?

Adams Heating & Cooling is a family-owned Kalamazoo company with 30+ years in the area and a Daikin comfort partner, and replacements and new installations start with a free estimate — a good place to ask these questions.

Asking which refrigerant a quoted system uses, and whether its indoor and outdoor parts are matched for it, makes quotes easier to compare.

Frequently asked questions

What does A2L mean on a refrigerant?

A2L is a safety class from ASHRAE Standard 34: "A" means lower toxicity, and "2L" means lower flammability, the class just above non-flammable.

Can R-410A systems still be installed after 2026?

Yes, if every specified component was manufactured in or imported into the United States before January 1, 2025. EPA removed the installation deadline for those systems in a final rule effective July 27, 2026.

Do I have to replace my R-410A air conditioner?

No. EPA's Technology Transitions limits apply to new equipment, not to a working R-410A system already in your home, which can keep being repaired and maintained.

Can I put R-454B into my R-410A system?

No. A system is charged with the refrigerant on its nameplate, and split systems are rated as matched indoor and outdoor components for one refrigerant.

What GWP limit applies to new home AC and heat pumps?

EPA's Technology Transitions rule sets a global warming potential limit of 700 for new residential and light commercial air conditioning and heat pump equipment, starting with equipment manufactured or imported from January 1, 2025.

Does a new A2L air conditioner need a permit in Michigan?

In most cases, yes. Replacing HVAC equipment typically needs a mechanical permit from your local building department, whatever refrigerant it uses; our Kalamazoo County permit guide lists who issues them.

Sources

  1. Federal Register — Phasedown of Hydrofluorocarbons: Reconsideration of Certain Regulatory Requirements (91 FR 31284) (accessed November 19, 2026)
  2. govinfo — Federal Register document 2026-10387 (accessed November 19, 2026)
  3. U.S. EPA — Technology Transitions HFC Restrictions by Sector (accessed November 19, 2026)
  4. U.S. Department of Energy — 2023 Central Air Conditioner and Heat Pump Standards FAQ (accessed November 19, 2026)
  5. City of Portage — Mechanical Information Sheet (accessed November 19, 2026)
  6. Oshtemo Charter Township — Codes Currently in Effect (accessed November 19, 2026)
  7. Pacific Northwest National Laboratory — Guide to Determining Climate Zone by County (accessed November 19, 2026)
  8. National Weather Service Grand Rapids — Kalamazoo Annual Climate Report (accessed November 19, 2026)

Second-Generation Family Owned

Ready When You Are — 24 Hours a Day

From quick fixes to full installs, the Adams family team has Southwest Michigan covered. One call puts a certified local tech on your schedule.

The Adams Guarantee
  • 24-hour emergency service
  • LEED & EPA Certified technicians on every job
  • Second-generation, family owned & operated